mirror of
https://gitlab.com/pholy/OSCAR-code.git
synced 2025-04-08 20:20:44 +00:00
Update FV023 and F5V0 summary parsers to parse the humidification at equipment-off.
Accordingly update ParseHumidifierSetting50Series to add a parameter controlling whether parsed settings should be imported or not, consistent with all other PRS1 humidifier parsers.
This commit is contained in:
parent
7028f20aaf
commit
05779eac4f
@ -4405,9 +4405,7 @@ bool PRS1DataChunk::ParseSummaryF0V23()
|
||||
}
|
||||
//CHECK_VALUES(data[pos+3], 0, 1); // TODO: may be related to ramp? 1-5 seems to have a ramp start or two
|
||||
//CHECK_VALUES(data[pos+4], 0x81, 0x80); // seems to be humidifier setting at end of session
|
||||
if (data[pos+4] && (((data[pos+4] & 0x80) == 0) || (data[pos+4] & 0x07) > 5)) {
|
||||
UNEXPECTED_VALUE(data[pos+4], "valid humidifier setting");
|
||||
}
|
||||
ParseHumidifierSetting50Series(data[pos+4]);
|
||||
break;
|
||||
/*
|
||||
case 5: // Unknown, but occasionally encountered
|
||||
@ -4503,7 +4501,7 @@ bool PRS1DataChunk::ParseSettingsF0V23(const unsigned char* data, int /*size*/)
|
||||
this->ParseFlexSetting(flex, cpapmode);
|
||||
|
||||
int humid = data[0x09];
|
||||
this->ParseHumidifierSetting50Series(humid);
|
||||
this->ParseHumidifierSetting50Series(humid, true);
|
||||
|
||||
// Tubing lock has no setting byte
|
||||
|
||||
@ -5675,7 +5673,7 @@ bool PRS1DataChunk::ParseSettingsF5V012(const unsigned char* data, int /*size*/)
|
||||
int pos;
|
||||
if (this->familyVersion == 0) { // TODO: either split this into two functions or use size to differentiate like FV3 parsers do
|
||||
// TODO: Is there another flag for F5V0? Reports say "Bypass System One Humidification" as an option?
|
||||
this->ParseHumidifierSetting50Series(data[0x0d]);
|
||||
this->ParseHumidifierSetting50Series(data[0x0d], true);
|
||||
pos = 0xe;
|
||||
} else {
|
||||
this->ParseHumidifierSettingF0V4(data[0x0d], data[0x0e], true); // 94 05, A0 4A F5V1; 93 09 F5V2
|
||||
@ -5825,7 +5823,11 @@ bool PRS1DataChunk::ParseSummaryF5V012(void)
|
||||
case 1: // Equipment Off
|
||||
tt += data[pos] | (data[pos+1] << 8);
|
||||
this->AddEvent(new PRS1ParsedSliceEvent(tt, EquipmentOff));
|
||||
/*
|
||||
if (this->familyVersion == 0) {
|
||||
CHECK_VALUE(data[pos+2], 1);
|
||||
ParseHumidifierSetting50Series(data[pos+3]);
|
||||
}
|
||||
/* Possibly F5V12?
|
||||
CHECK_VALUE(data[pos+2] & ~(0x40|8|4|2|1), 0); // ???, seen various bit combinations
|
||||
//CHECK_VALUE(data[pos+3], 0x19); // 0x17, 0x16
|
||||
//CHECK_VALUES(data[pos+4], 0, 1); // or 2
|
||||
@ -5983,15 +5985,17 @@ void PRS1DataChunk::ParseFlexSetting(quint8 flex, int cpapmode)
|
||||
// 0x82 = 2, bypass = no
|
||||
|
||||
// TODO: PRS1_SETTING_HUMID_STATUS is ambiguous: we probably want connected vs. not, which should be distinct from system one vs. classic, etc.
|
||||
void PRS1DataChunk::ParseHumidifierSetting50Series(int humid)
|
||||
void PRS1DataChunk::ParseHumidifierSetting50Series(int humid, bool add_setting)
|
||||
{
|
||||
if (humid & (0x40 | 0x20 | 0x10 | 0x08)) UNEXPECTED_VALUE(humid, "known bits");
|
||||
|
||||
bool humidifier_present = ((humid & 0x80) != 0);
|
||||
int humidlevel = humid & 7;
|
||||
bool humidifier_present = ((humid & 0x80) != 0); // humidifier connected
|
||||
int humidlevel = humid & 7; // humidification level
|
||||
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_HUMID_STATUS, humidifier_present)); // Humidifier Connected
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_HUMID_LEVEL, humidlevel)); // Humidifier Value
|
||||
if (add_setting) {
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_HUMID_STATUS, humidifier_present));
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_HUMID_LEVEL, humidlevel));
|
||||
}
|
||||
|
||||
// Check for truly unexpected values:
|
||||
if (humidlevel > 5) UNEXPECTED_VALUE(humidlevel, "<= 5");
|
||||
|
@ -169,7 +169,7 @@ public:
|
||||
void ParseFlexSetting(quint8 flex, int prs1mode);
|
||||
|
||||
//! \brief Parse an humidifier setting byte from a .000 or .001 containing compliance/summary data for original System One (50-Series) machines: F0V23 and F5V0
|
||||
void ParseHumidifierSetting50Series(int humid);
|
||||
void ParseHumidifierSetting50Series(int humid, bool add_setting=false);
|
||||
|
||||
//! \brief Parse an humidifier setting byte from a .000 or .001 containing compliance/summary data for F0V4 and F5V012 machines and maybe others
|
||||
void ParseHumidifierSettingF0V4(unsigned char humid1, unsigned char humid2, bool add_setting=false);
|
||||
|
Loading…
Reference in New Issue