mirror of
https://gitlab.com/pholy/OSCAR-code.git
synced 2025-04-05 18:50:44 +00:00
Clean up remaining DreamStation parsing warnings.
This commit is contained in:
parent
d0903ce3bd
commit
4527a7091d
@ -3903,7 +3903,7 @@ void PRS1DataChunk::ParseHumidifierSettingF0V6(unsigned char byte1, unsigned cha
|
||||
if (humidifier_present) {
|
||||
if (humidlevel > 5 || humidlevel < 0) UNEXPECTED_VALUE(humidlevel, "0-5"); // 0=off is valid when a humidifier is attached
|
||||
if (humid == 2) { // heated tube
|
||||
if (tubelevel > 5 || tubelevel < 1) UNEXPECTED_VALUE(tubelevel, "1-5"); // TODO: maybe this is only if heated tube?
|
||||
if (tubelevel > 5 || tubelevel < 0) UNEXPECTED_VALUE(tubelevel, "0-5"); // TODO: maybe this is only if heated tube? 0=off is valid even in heated tube mode
|
||||
}
|
||||
}
|
||||
|
||||
@ -3975,8 +3975,8 @@ bool PRS1DataChunk::ParseSettingsF0V6(const unsigned char* data, int size)
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_CPAP_MODE, (int) cpapmode));
|
||||
break;
|
||||
case 1: // ???
|
||||
if (data[pos] != 0) {
|
||||
CHECK_VALUES(data[pos], 1, 2); // 1 when EZ-Start is enabled? 2 when Auto-Trial?
|
||||
if (data[pos] != 0 && data[pos] != 3) {
|
||||
CHECK_VALUES(data[pos], 1, 2); // 1 when EZ-Start is enabled? 2 when Auto-Trial? 3 when Auto-Trial is off or Opti-Start isn't off?
|
||||
}
|
||||
if (len == 2) { // 400G has extra byte
|
||||
CHECK_VALUE(data[pos+1], 0);
|
||||
@ -3992,7 +3992,10 @@ bool PRS1DataChunk::ParseSettingsF0V6(const unsigned char* data, int size)
|
||||
min_pressure = data[pos]; // Min Setting on pressure graph
|
||||
max_pressure = data[pos+1]; // Max Setting on pressure graph
|
||||
pressure = data[pos+2]; // CPAP on pressure graph and CPAP-Check Pressure on settings detail
|
||||
CHECK_VALUE(pressure, 0x5a);
|
||||
// This seems to be the initial pressure. If the pressure changes mid-session, the pressure
|
||||
// graph will show either the changed pressure or the majority pressure, not sure which.
|
||||
// The time of change is most likely in the events file. See slice 6 for ending pressure.
|
||||
//CHECK_VALUE(pressure, 0x5a);
|
||||
this->AddEvent(new PRS1PressureSettingEvent(PRS1_SETTING_PRESSURE, pressure));
|
||||
break;
|
||||
case 0x0d: // AutoCPAP pressure setting
|
||||
@ -4025,9 +4028,10 @@ bool PRS1DataChunk::ParseSettingsF0V6(const unsigned char* data, int size)
|
||||
case 0x10: // Auto-Trial mode
|
||||
CHECK_VALUE(cpapmode, MODE_CPAP); // the mode setting is CPAP, even though it's operating in APAP mode
|
||||
cpapmode = MODE_APAP; // but categorize it now as APAP, since that's what it's really doing
|
||||
CHECK_VALUE(data[pos], 30); // Auto-Trial Duration
|
||||
CHECK_VALUES(data[pos], 30, 5); // Auto-Trial Duration
|
||||
min_pressure = data[pos+1];
|
||||
max_pressure = data[pos+2];
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_CPAP_MODE, (int) cpapmode));
|
||||
this->AddEvent(new PRS1PressureSettingEvent(PRS1_SETTING_PRESSURE_MIN, min_pressure));
|
||||
this->AddEvent(new PRS1PressureSettingEvent(PRS1_SETTING_PRESSURE_MAX, max_pressure));
|
||||
break;
|
||||
@ -4047,11 +4051,11 @@ bool PRS1DataChunk::ParseSettingsF0V6(const unsigned char* data, int size)
|
||||
break;
|
||||
case 0x2e:
|
||||
if (data[pos] != 0) {
|
||||
CHECK_VALUES(data[pos], 0x80, 0x90); // maybe flex related? 0x80 when c-flex? 0x90 when c-flex+?, 0x00 when no flex
|
||||
CHECK_VALUES(data[pos], 0x80, 0x90); // maybe flex related? 0x80 when c-flex? 0x90 when c-flex+ or A-flex?, 0x00 when no flex
|
||||
}
|
||||
break;
|
||||
case 0x2f:
|
||||
CHECK_VALUE(data[pos], 0); // maybe flex related? 0x00 when c-flex and c-flex+?
|
||||
case 0x2f: // Flex lock
|
||||
CHECK_VALUES(data[pos], 0, 0x80);
|
||||
break;
|
||||
case 0x30: // Flex level
|
||||
this->AddEvent(new PRS1ParsedSettingEvent(PRS1_SETTING_FLEX_LEVEL, data[pos]));
|
||||
@ -4075,8 +4079,10 @@ bool PRS1DataChunk::ParseSettingsF0V6(const unsigned char* data, int size)
|
||||
CHECK_VALUES(data[pos], 2, 1); // tubing type? 15HT = 2, 15 = 1, 22 = 0?
|
||||
}
|
||||
break;
|
||||
case 0x40: // new to 400G, alternate tubing type? appears after 0x39 and before 0x3c, 12mm = 3?
|
||||
CHECK_VALUE(data[pos], 3);
|
||||
case 0x40: // new to 400G, also seen on 500X110, alternate tubing type? appears after 0x39 and before 0x3c
|
||||
if (data[pos] != 3) {
|
||||
CHECK_VALUES(data[pos], 1, 2); // 1 = 15mm, 2 = 15HT, 3 = 12mm
|
||||
}
|
||||
break;
|
||||
case 0x3c:
|
||||
CHECK_VALUES(data[pos], 0, 0x80); // 0x80 maybe show AHI?
|
||||
@ -4186,10 +4192,10 @@ bool PRS1DataChunk::ParseSummaryF0V6(void)
|
||||
CHECK_VALUE(data[pos+5], 0x00);
|
||||
//CHECK_VALUES(data[pos+6], 0x1e, 0x35); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+7], 0x00);
|
||||
//CHECK_VALUES(data[pos+8], 0x8c, 0x4c); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+9], 0x00);
|
||||
//CHECK_VALUES(data[pos+0xa], 0xbb, 0x00); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+0xb], 0x00);
|
||||
//CHECK_VALUES(data[pos+8], 0x8c, 0x4c); // 16-bit value, not sure what
|
||||
//CHECK_VALUE(data[pos+9], 0x00);
|
||||
//CHECK_VALUES(data[pos+0xa], 0xbb, 0x00); // 16-bit minutes in large leak
|
||||
//CHECK_VALUE(data[pos+0xb], 0x00);
|
||||
//CHECK_VALUES(data[pos+0xc], 0x15, 0x02); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+0xd], 0x00);
|
||||
//CHECK_VALUES(data[pos+0xe], 0x01, 0x00); // 16-bit VS count
|
||||
@ -4258,22 +4264,23 @@ bool PRS1DataChunk::ParseSummaryF0V6(void)
|
||||
//CHECK_VALUE(data[pos+3], 0x64); // seems to match 90% IPAP
|
||||
break;
|
||||
case 0x0b:
|
||||
// CPAP-Check related? follows 3, so first two bytes may be time delta
|
||||
CHECK_VALUE(data[pos], 3);
|
||||
CHECK_VALUE(data[pos+1], 0);
|
||||
CHECK_VALUE(data[pos+2], 0);
|
||||
// CPAP-Check related? follows 3 in CPAP-Check mode
|
||||
tt += data[pos] | (data[pos+1] << 8); // This adds to the total duration (otherwise it won't match report)
|
||||
//CHECK_VALUE(data[pos+2], 0); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+3], 0);
|
||||
CHECK_VALUE(data[pos+4], 0);
|
||||
//CHECK_VALUE(data[pos+4], 0); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+5], 0);
|
||||
CHECK_VALUE(data[pos+6], 0);
|
||||
//CHECK_VALUE(data[pos+6], 0); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+7], 0);
|
||||
CHECK_VALUE(data[pos+8], 0);
|
||||
//CHECK_VALUE(data[pos+8], 0); // probably 16-bit value
|
||||
CHECK_VALUE(data[pos+9], 0);
|
||||
CHECK_VALUE(data[pos+0xa], 0);
|
||||
//CHECK_VALUES(data[pos+0xa], 20, 60); // or 0? 44 when changed pressure mid-session?
|
||||
break;
|
||||
case 0x06:
|
||||
// CPAP-Check related? follows 4, before 8, looks like a pressure value
|
||||
CHECK_VALUES(data[pos], 90, 60); // maybe CPAP-Check pressure, also matches EZ-Start Pressure
|
||||
// Maybe starting pressure? follows 4, before 8, looks like a pressure value, seen with CPAP-Check and EZ-Start
|
||||
// Maybe ending pressure: matches ending CPAP-Check pressure if it changes mid-session.
|
||||
// TODO: The daily details will show when it changed, so maybe there's an event that indicates a pressure change.
|
||||
//CHECK_VALUES(data[pos], 90, 60); // maybe CPAP-Check pressure, also matches EZ-Start Pressure
|
||||
break;
|
||||
default:
|
||||
UNEXPECTED_VALUE(code, "known slice code");
|
||||
|