From 7239923dbdd68b316ba56af281ce3e887509bc4b Mon Sep 17 00:00:00 2001
From: sawinglogz <3787776-sawinglogz@users.noreply.gitlab.com>
Date: Sun, 29 Mar 2020 12:55:20 -0400
Subject: [PATCH] Add improvements to beta-2 missing from the release notes.
---
oscar/docs/release_notes.html | 17 ++++++++++++++++-
1 file changed, 16 insertions(+), 1 deletion(-)
diff --git a/oscar/docs/release_notes.html b/oscar/docs/release_notes.html
index a66e174a..349532af 100644
--- a/oscar/docs/release_notes.html
+++ b/oscar/docs/release_notes.html
@@ -20,9 +20,24 @@
- Portions of OSCAR are © 2019-2020 by The OSCAR Team
- [new] Add preliminary support for Viatom/Wellue pulse oximeters
+- [new] Add support for Dreem hypnograms
+- [new] Extensive re-organization of the ResMed loader to facilitate understanding and future improvements
+- [new] Additional Philips Respironics machines tested and fully supported:
+
+ - DreamStation Auto CPAP (500X130)
+
+- [new] Add a menu option to create a zip from an SD card
- [new] Ask where to save screenshots
+- [new] Alert users when unexpected Philips Respironics data is encountered during import
+- [fix] Add support for CPAP mode on DreamStation BiPAP S/T and AVAPS
+- [fix] Pinch-to-zoom now works as expected
+- [fix] The Philips Respironics loader now respects the "ignore old sessions" preference
+- [fix] Improved handling of discontinuous Philips Respironics data
- [fix] Improved import of Philips Respironics flex and humidification settings
-- [new]Extensive re-organization of the ResMed loader to facilitate understanding and future improvements
+- [fix] Fix incorrect display of tube diameter on some Philips Respironics machines
+- [fix] Fix missing "Bi-Flex" label for bi-level DreamStations
+- [fix] Fix crashes in ZEO loader
+- [fix] Fix several memory leaks