mirror of
https://gitlab.com/pholy/OSCAR-code.git
synced 2025-04-05 18:50:44 +00:00
Disable oximeter download tests by default for now.
They're not yet stable enough to be enabled as regression tests in master.
This commit is contained in:
parent
eb5bef5fba
commit
d88084a342
@ -92,7 +92,9 @@ void DeviceConnectionTests::testSerialPortScanning()
|
||||
list3 = SerialPortInfo::availablePorts();
|
||||
}
|
||||
|
||||
#define ENABLE 0
|
||||
|
||||
#if ENABLE
|
||||
static void testDownload(const QString & loaderName)
|
||||
{
|
||||
SerialOximeter * oxi = qobject_cast<SerialOximeter*>(lookupLoader(loaderName));
|
||||
@ -125,6 +127,7 @@ static void testDownload(const QString & loaderName)
|
||||
}
|
||||
oxi->trashRecords();
|
||||
}
|
||||
#endif
|
||||
|
||||
void DeviceConnectionTests::testOximeterConnection()
|
||||
{
|
||||
@ -135,6 +138,7 @@ void DeviceConnectionTests::testOximeterConnection()
|
||||
const char* argv = "test";
|
||||
QCoreApplication app(argc, (char**) &argv);
|
||||
|
||||
#if ENABLE
|
||||
DeviceConnectionManager & devices = DeviceConnectionManager::getInstance();
|
||||
/*
|
||||
QString string;
|
||||
@ -165,6 +169,10 @@ void DeviceConnectionTests::testOximeterConnection()
|
||||
qDebug().noquote() << string;
|
||||
*/
|
||||
|
||||
QFile out("test.xml");
|
||||
Q_ASSERT(out.open(QFile::ReadWrite));
|
||||
devices.record(&out);
|
||||
|
||||
QFile file("cms50f37.xml");
|
||||
if (!file.exists()) {
|
||||
qDebug() << "Recording oximeter connection";
|
||||
@ -181,4 +189,5 @@ void DeviceConnectionTests::testOximeterConnection()
|
||||
testDownload(cms50f37_class_name);
|
||||
devices.replay(nullptr);
|
||||
file.close();
|
||||
#endif
|
||||
}
|
||||
|
Loading…
Reference in New Issue