From eaf88b0d2349c00f020cf53cdfdc8985c51a0a7f Mon Sep 17 00:00:00 2001
From: Guy Scharf
Date: Wed, 3 Nov 2021 18:06:50 -0700
Subject: [PATCH] Add 95% flow limitation to Therapy Efficacy section on
Statistics page Flow limitation index is already there, for machines that
report an index. This adds flow limitation statistics to report for ResMed
machines.
---
Htmldocs/release_notes.html | 1 +
oscar/statistics.cpp | 1 +
2 files changed, 2 insertions(+)
diff --git a/Htmldocs/release_notes.html b/Htmldocs/release_notes.html
index a6fc9ce3..fffc5dd5 100644
--- a/Htmldocs/release_notes.html
+++ b/Htmldocs/release_notes.html
@@ -16,6 +16,7 @@
The OSCAR Team
- [new] Add support for new settings codes in recently manufactured 700X110 DreamStations.
+ - [new] Add 95% flow limitation to Therapy Efficacy section on Statistics page.
- [fix] Correct SleepStyle machines sometimes identified as Icon machines.
- [fix] Update copyright notices in html files.
- [fix] Correct value display on exact data points, and near session boundaries with drift.
diff --git a/oscar/statistics.cpp b/oscar/statistics.cpp
index 518a74a6..9effb1df 100644
--- a/oscar/statistics.cpp
+++ b/oscar/statistics.cpp
@@ -548,6 +548,7 @@ Statistics::Statistics(QObject *parent) :
rows.push_back(StatisticsRow("Apnea", SC_CPH, MT_CPAP));
rows.push_back(StatisticsRow("ClearAirway", SC_CPH, MT_CPAP));
rows.push_back(StatisticsRow("FlowLimit", SC_CPH, MT_CPAP));
+ rows.push_back(StatisticsRow("FLG", SC_90P, MT_CPAP));
rows.push_back(StatisticsRow("RERA", SC_CPH, MT_CPAP));
rows.push_back(StatisticsRow("SensAwake", SC_CPH, MT_CPAP));
rows.push_back(StatisticsRow("CSR", SC_SPH, MT_CPAP));