Guy Scharf
5c88770bfe
Improve language in error message windows
2020-06-03 10:02:20 -07:00
sawinglogz
d77ee5025a
Comment out BrokenSummary and BrokenWaveform channels, as they are no longer used.
...
No functional change.
2020-03-24 13:50:30 -04:00
sawinglogz
d4fd330a31
Fix regression introduced by cb57643
.
...
The Test1/2 channels were no longer initialized. As a result, all
Test1/2 data got merged into channel 0.
2020-03-08 16:27:18 -04:00
Phil Olynyk
11b1d9a045
Roll the VAuto TrigCycEvent into the S0 VPAP-S RespEvent type
2020-02-21 21:41:00 -05:00
Phil Olynyk
da29e35766
Merge master with tidy-edf-parser
2020-02-02 14:52:02 -05:00
Phil Olynyk
0fd25f2f4e
Add delete (obj) to clean up memory leaks
2020-01-30 19:52:37 -05:00
sawinglogz
8ef068af7e
Fix ZEO loader to handle MyZeo 0.3.1 date formatting.
...
Also make the UI more informative and fix up the regression test output.
2020-01-29 16:21:42 -05:00
sawinglogz
cb576437ab
Clean up noise and memory leaks in unit tests.
2020-01-29 09:10:29 -05:00
sawinglogz
4ebc7d3681
Rename POS_Motion channel to POS_Movement to match Viatom report terminology.
...
Also move database updates to Open() rather than at each file imported.
2020-01-26 19:50:18 -05:00
sawinglogz
66f13f3143
Initial commit of contributed Viatom SpO2 loader.
...
Diff applied from the following commit by dave madden <dhm@mersenne.com>,
replacing tabs with spaces:
fa38850503
2020-01-23 12:57:44 -05:00
sawinglogz
e74bfbf2fd
Change the channel IDs for pressure/IPAP/EPAP-Set events so that the previous fix always works.
...
Settings are written as soon as a day is viewed, so anybody who viewed
their PRS1 data prior to the previous commit would have settings with the
channels expressly disabled. Changing the channel ID forces them to be
treated as new, and thus default to on.
2019-12-27 22:06:31 -06:00
sawinglogz
9a25647c25
Add initial support for PRS1 settings channel (as distinct from statistics).
...
Right now this results in slightly confusing graphs, since sometimes
the IPAP/EPAP data for a machine is primarily reported by its settings
events, and for other machines by its statistics events. Also, the
"average" pressure on F0 looks like it might be effectivley EPAP in
single-pressure mode rather than the true average in bi-level mode.
Once we decide on the best presentation, we can either update the importer
or the display to show the most helpful channels for a given session.
2019-10-29 11:14:57 -04:00
Seeker4
aeffae09fc
Standard and Advanced graphs apparently working, still with lots of diagnostics.
2019-09-01 22:14:36 -07:00
Seeker4
afdcd0bbc4
First step in Daily graphs rework: replace many hard-coded strings as STR_GRAPH_* variables for keys to graphs.
2019-08-31 17:56:53 -07:00
Phil Olynyk
6f34f2605a
Clarified Unclassified Apnea description
2019-03-25 19:34:01 -04:00
Phil Olynyk
108e0354d9
Change OSCR to OSCAR in cpp, h, ui, and html files
2019-02-23 19:58:25 -05:00
Phil Olynyk
17b53482bd
Change folder and file name from oscr to oscar
2019-02-22 19:23:39 -05:00