/* -*- Mode: C++; tab-width: 8; indent-tabs-mode: nil; c-basic-offset: 4 -*- * vim: set ts=8 sts=4 et sw=4 tw=99: * * SleepLib CMS50X Loader Implementation * * Copyright (c) 2011 Mark Watkins * * This file is subject to the terms and conditions of the GNU General Public * License. See the file COPYING in the main directory of the Linux * distribution for more details. */ //******************************************************************************************** /// IMPORTANT!!! //******************************************************************************************** // Please INCREMENT the cms50_data_version in cms50_loader.h when making changes to this loader // that change loader behaviour or modify channels. //******************************************************************************************** #include #include #include #include #include #include #include #include #include #include #include #include using namespace std; #include "cms50_loader.h" #include "SleepLib/machine.h" #include "SleepLib/session.h" extern QProgressBar *qprogress; CMS50Loader::CMS50Loader() { m_type = MT_OXIMETER; m_abort = false; m_streaming = false; m_importing = false; imp_callbacks = 0; m_vendorID = 0x10c4; m_productID = 0xea60; startTimer.setParent(this); resetTimer.setParent(this); } CMS50Loader::~CMS50Loader() { } bool CMS50Loader::Detect(const QString &path) { Q_UNUSED(path); return false; } int CMS50Loader::Open(QString path, Profile *profile) { // Only one active Oximeter module at a time, set in preferences Q_UNUSED(profile) m_itemCnt = 0; m_itemTotal = 0; m_abort = false; m_importing = false; started_import = false; started_reading = false; finished_import = false; imp_callbacks = 0; cb_reset = 0; m_time.start(); // Cheating using path for two serial oximetry modes if (path.compare("import") == 0) { setStatus(IMPORTING); startTimer.stop(); startImportTimeout(); return 1; } else if (path.compare("live") == 0) { m_startTime = oxitime = QDateTime::currentDateTime(); setStatus(LIVE); return 1; } QString ext = path.section(".",1); if ((ext.compare("spo", Qt::CaseInsensitive)==0) || (ext.compare("spor", Qt::CaseInsensitive)==0)) { // try to read and process SpoR file.. return readSpoRFile(path) ? 1 : 0; } return 0; } void CMS50Loader::processBytes(QByteArray bytes) { // Sync to start of message type we are interested in quint8 c; quint8 msgcode = 0x80; int idx=0; int bytesread = bytes.size(); while ((idx < bytesread) && (((c=(quint8)bytes.at(idx)) & msgcode)!=msgcode)) { if (buffer.length()>0) { // If buffer is the start of a valid but short frame, add to it.. buffer.append(c); }// otherwise dump these bytes, as they are out of sequence. ++idx; } // Copy the rest to the buffer. buffer.append(bytes.mid(idx)); int available = buffer.length(); switch (status()) { case IMPORTING: idx = doImportMode(); break; case LIVE: idx = doLiveMode(); break; default: qDebug() << "Device mode not supported by" << ClassName(); } if (idx >= available) { buffer.clear(); } else if (idx > 0) { // Trim any processed bytes from the buffer. buffer = buffer.mid(idx); } if (buffer.length() > 0) { // If what's left doesn't start with a marker bit, dump it if (((unsigned char)buffer.at(0) & 0x80) != 0x80) { buffer.clear(); } } } int CMS50Loader::doImportMode() { int available = buffer.size(); Q_ASSERT(!finished_import); int hour,minute; int idx = 0; while (idx < available) { unsigned char c=(unsigned char)buffer.at(idx); if (!started_import) { if (c != 0xf2) { // If not started, continue scanning for a valie header. idx++; continue; } else { received_bytes=0; hour=(unsigned char)buffer.at(idx + 1) & 0x7f; minute=(unsigned char)buffer.at(idx + 2) & 0x7f; qDebug() << QString("Receiving Oximeter transmission %1:%2").arg(hour).arg(minute); // set importing to true or whatever.. finished_import = false; started_import = true; started_reading = false; m_importing = true; m_itemCnt=0; m_itemTotal=5000; killTimers(); qDebug() << "Getting ready for import"; oxirec.clear(); oxirec.reserve(10000); QDate oda=QDate::currentDate(); QTime oti=QTime(hour,minute); // Only CMS50E/F's have a realtime clock. CMS50D+ will set this to midnight cms50dplus = (hour == 0) && (minute == 0); // Either a CMS50D+ or it's really midnight, set a flag anyway for later to help choose the right sync time // If the oximeter record time is more than the current time, then assume it was from the day before // Or should I use split time preference instead??? Foggy Confusements.. if (oti > QTime::currentTime()) { oda = oda.addDays(-1); } m_startTime = oxitime = QDateTime(oda,oti); // Convert it to UTC oxitime = oxitime.toTimeSpec(Qt::UTC); qDebug() << "Session start (according to CMS50)" << oxitime<< hex << buffer.at(idx + 1) << buffer.at(idx + 2) << ":" << dec << hour << minute ; cb_reset = 1; // CMS50D+ needs an end timer because it just stops dead after uploading resetTimer.singleShot(2000,this,SLOT(resetImportTimeout())); } idx += 3; } else { // have started import if (c == 0xf2) { // Header is repeated 3 times, ignore the extras hour=(unsigned char)buffer.at(idx + 1) & 0x7f; minute=(unsigned char)buffer.at(idx + 2) & 0x7f; // check.. idx += 3; continue; } else if ((c & 0xf0) == 0xf0) { // Data trio started_reading=true; // Sometimes errornous crap is sent after data rec header // Recording import if ((idx + 2) >= available) { return idx; } quint8 pulse=(unsigned char)buffer.at(idx + 1) & 0x7f | ((c & 1) << 7); quint8 spo2=(unsigned char)buffer.at(idx + 2) & 0xff; oxirec.append(OxiRecord(pulse,spo2)); received_bytes+=3; // TODO: Store the data to the session m_itemCnt++; m_itemCnt=m_itemCnt % m_itemTotal; emit updateProgress(m_itemCnt, m_itemTotal); idx += 3; } else if (!started_reading) { // have not got a valid trio yet, skip... idx += 1; } else { //Completed finished_import = true; killTimers(); closeDevice(); m_importing = false; m_status = NEUTRAL; emit importComplete(this); return available; imp_callbacks = cb_reset = 0; return available; } } } if (!started_import) { imp_callbacks = 0; } else { imp_callbacks++; } return idx; } int CMS50Loader::doLiveMode() { int available = buffer.size(); int idx = 0; QByteArray plethy; while (idx < available-5) { if (((unsigned char)buffer.at(idx) & 0x80) != 0x80) { idx++; continue; } int pwave=(unsigned char)buffer.at(idx + 1); int pbeat=(unsigned char)buffer.at(idx + 2); int pulse=((unsigned char)buffer.at(idx + 3) & 0x7f) | ((pbeat & 0x40) << 1); int spo2=(unsigned char)buffer.at(idx + 4) & 0x7f; oxirec.append(OxiRecord(pulse, spo2)); plethy.append(pwave); idx += 5; } emit updatePlethy(plethy); return idx; } void CMS50Loader::resetDevice() // Switch CMS50D+ device to live streaming mode { //qDebug() << "Sending reset code to CMS50 device"; //m_port->flush(); static unsigned char b1[3]={0xf6,0xf6,0xf6}; if (serial.write((char *)b1,3)==-1) { qDebug() << "Couldn't write data reset bytes to CMS50"; } } void CMS50Loader::requestData() // Switch CMS50D+ device to record transmission mode { static unsigned char b1[2]={0xf5,0xf5}; //qDebug() << "Sending request code to CMS50 device"; if (serial.write((char *)b1,2)==-1) { qDebug() << "Couldn't write data request bytes to CMS50"; } } void CMS50Loader::killTimers() { startTimer.stop(); resetTimer.stop(); } void CMS50Loader::startImportTimeout() { if (!m_streaming) return; if (started_import) { return; } Q_ASSERT(finished_import == false); //qDebug() << "Starting oximeter import timeout"; // Wait until events really are jammed on the CMS50D+ before re-requesting data. const int delay = 500; if (m_abort) { m_streaming = false; closeDevice(); return; } if (imp_callbacks == 0) { // Frozen, but still hasn't started? m_itemCnt = m_time.elapsed(); if (m_itemCnt > START_TIMEOUT) { // Give up after START_TIMEOUT closeDevice(); abort(); QMessageBox::warning(nullptr, STR_MessageBox_Error, "

"+tr("Could not get data transmission from oximeter.")+"

"+tr("Please ensure you select 'upload' from the oximeter devices menu.")+"

"); return; } else { // Note: Newer CMS50 devices transmit from user input, but there is no way of differentiating between models requestData(); } emit updateProgress(m_itemCnt, START_TIMEOUT); // Schedule another callback to make sure it's started startTimer.singleShot(delay, this, SLOT(startImportTimeout())); } } void CMS50Loader::resetImportTimeout() { if (finished_import) { return; } if (imp_callbacks != cb_reset) { // Still receiving data.. reset timer qDebug() << "Still receiving data in resetImportTimeout()" << imp_callbacks << cb_reset; if (resetTimer.isActive()) resetTimer.stop(); if (!finished_import) resetTimer.singleShot(2000, this, SLOT(resetImportTimeout())); } else { qDebug() << "Oximeter device stopped transmitting.. Transfer complete"; // We were importing, but now are done if (!finished_import && (started_import && started_reading)) { qDebug() << "Switching CMS50 back to live mode and finalizing import"; // Turn back on live streaming so the end of capture can be dealt with resetTimer.stop(); serial.flush(); resetDevice(); // Send Reset to CMS50D+ //started_import = false; finished_import = true; //m_streaming=false; //closeDevice(); //emit transferComplete(); //doImportComplete(); return; } qDebug() << "Should CMS50 resetImportTimeout reach here?"; // else what??? } cb_reset=imp_callbacks; } bool CMS50Loader::readSpoRFile(QString path) { QFile file(path); if (!file.exists() || !file.isReadable()) { return false; } file.open(QFile::ReadOnly); QByteArray data; data = file.readAll(); long size = data.size(); // position data stream starts at int pos = ((unsigned char)data.at(1) << 8) | (unsigned char)data.at(0); // Read date and time (it's a 16bit charset) char dchr[20]; int j = 0; for (int i = 0; i < 18 * 2; i += 2) { dchr[j++] = data.at(8 + i); } dchr[j] = 0; QString dstr(dchr); oxitime = QDateTime::fromString(dstr, "MM/dd/yy HH:mm:ss"); if (oxitime.date().year() < 2000) { oxitime = oxitime.addYears(100); } unsigned char o2, pr; // Read all Pulse and SPO2 data for (int i = pos; i < size - 2;) { o2 = (unsigned char)(data.at(i + 1)); pr = (unsigned char)(data.at(i + 0)); oxirec.append(OxiRecord(pr, o2)); i += 2; } // processing gets done later return true; } Machine *CMS50Loader::CreateMachine(Profile *profile) { if (!profile) { return nullptr; } // NOTE: This only allows for one CMS50 machine per profile.. // Upgrading their oximeter will use this same record.. QList ml = profile->GetMachines(MT_OXIMETER); for (QList::iterator i = ml.begin(); i != ml.end(); i++) { if ((*i)->GetClass() == cms50_class_name) { return (*i); break; } } qDebug() << "Create CMS50 Machine Record"; Machine *m = new Oximeter(profile, 0); m->SetClass(cms50_class_name); m->properties[STR_PROP_Brand] = "Contec"; m->properties[STR_PROP_Model] = "CMS50X"; m->properties[STR_PROP_DataVersion] = QString::number(cms50_data_version); profile->AddMachine(m); QString path = "{" + STR_GEN_DataFolder + "}/" + m->GetClass() + "_" + m->hexid() + "/"; m->properties[STR_PROP_Path] = path; return m; } void CMS50Loader::process() { int size=oxirec.size(); if (size<10) return; // EventList *PULSE=new EventList(EVL_Event); // EventList *SPO2=new EventList(EVL_Event); // quint64 ti = oxitime.toMSecsSinceEpoch(); // for (int i=0; i < size; ++i) { // //PULSE->AddWaveform // } // qDebug() << "Processing" << oxirec.size() << "oximetry records"; } static bool cms50_initialized = false; void CMS50Loader::Register() { if (cms50_initialized) { return; } qDebug() << "Registering CMS50Loader"; RegisterLoader(new CMS50Loader()); cms50_initialized = true; }